BXWSV - FX-UNIVERSAL FIXER

  • MSDS: BXWSV
  • Manufacturer: MILES INC
  • Product Name: FX-UNIVERSAL FIXER
  • National Stock Number: 6750-00N014108
Product Identification

Product ID:FX-UNIVERSAL FIXER
MSDS Date:07/01/1993
FSC:6750
NIIN:00N014108
MSDS Number: BXWSV

Responsible Party
MILES INC
100 CHALLENGER RD
RIDGEFIELD PARK, NJ 07660
US

Emergency Phone: 201-440-2500

Info Phone: 212-971-0260

Cage: MILES

Contractor
MILES INC
PITTSBURGH, PA 15205-9741 US

Telephone: 800-662-2927

Cage: MILES

Ingredients

AMMONIUM HYDROXIDE (CERCLA)

CAS: 1336-21-6

RTECS: BQ9625000

Fraction By Weight: 1-5%

OSHA PEL N/K

ACGIH TLV: N/K

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 35-40%

OSHA PEL N/K

ACGIH TLV: N/K


SODIUM SULFITE

CAS: 7757-83-7

RTECS: WE2150000

Fraction By Weight: 10-15%

OSHA PEL N/K

ACGIH TLV: N/K


THIOSULFURIC ACID, DIAMMONIUM SALT; (AMMONIUM THIOSULFATE)

CAS: 7783-18-8

RTECS: XN6465000

Fraction By Weight: 45-50%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE (NOTE: PERTAINS TO FINISHED
PRODUCT): EYE/SKIN CONTACT: MAY CAUSE IRRITATION. INHALATION:
NORMALLY NO PROBLEM, BUT INHALATION OF MIST COULD CAUSE RESPIRATORY
IRRITATION. INGESTION: MAY CAUSE IRR ITATION OF THE MUCOUS
MEMBRANES OR DIGESTIVE TRACT. CHRONIC (NOTE: PERTAINS TO EACH
LISTED INGRED): (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: A COMPUTERIZED LITERATURE SEARCH OF
NATIONAL DATABASES DID NOT YIELD ANY CHRONIC EFFECTS ASSOCIATED
WITH THESE MATERIALS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: IMMEDIATELY FLUSH WITH PLENTY OF RUNNING WATER FOR AT
LEAST 15 MINUTES. OBTAIN MEDICAL ATTENTION. SKIN: FLUSH AFFECTED
AREAS PROMPTLY WITH WATER FOR 15 MINUTES. REMOVE CONTAMINATED
CLOTHING. IN CASE OF CONTINUED IRRITATION CONSULT MD. INHAL:
REMOVE TO FRESH AIR. INGEST: OBTAIN IMMEDIATE MEDICAL ATTENTION.

Fire Fighting

Flash Point:NONCOMBUSTIBLE
Extinguishing Media:ANY APPLICABLE TO PRIMARY CAUSE OF FIRE.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . EVACUATE PERSONNEL TO A SAFE AREA. KEEP
PERSONNEL REMOVED AND UPWIND OF FIRE.
Unusual Fire/Explosion Hazard:WHEN HEATED TO DECOMPOSITION EMISSION OF
TOXIC FUMES OF SO*2 IS POSSIBLE.

Accidental Release

Spill Release Procedures:NOTE: REVIEW FIRE FIGHTING MEASURES & EXPOS
CTL/PERSONAL PROT SECTIONS BEFORE PROCEEDING W/CLEAN UP. USE APPROP
PERSONAL PROT EQUIP DURING CLEAN UP. DIKE SPILL. PVNT LIQ FROM
ENTERING SEWERS, WATERWAY S OR LOW AREAS. SOAK UP W/SAWDUST, SAND,
(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID EYE & SKIN CONTACT & STORE IN
WELL-VENTILATED AREA. KEEP CONTAINER TIGHTLY CLOSED. DO NOT STORE
WITH INCOMPATIBLE MATERIALS.
Other Precautions:DO NOT STORE OR CONSUME FOOD, DRINK OR TOBACCO IN
AREA WHERE THEY MAY BECOME CONTAMINATED WITH THIS MATERIAL.

Exposure Controls

Respiratory Protection:NONE NEEDED WITH WORKING MIXTURES AND NORMAL
ROOM VENTILATION (10 CHANGES OF AIR PER HOUR). USE NIOSH/MSHA
APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:ROOM VENT IS SUFFICIENT. AVOID USE OF PROD IN UNVENT AREAS.
ALWAYS CONTROL AIRBORNE LEVELS BELOW EXPOSURE (SUPDAT)
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:FOR SKIN PROTECTION USE CHEMICAL RESISTANT
APRONS. DISPOSABLE COVERALLS ARE OPTIONAL AND DISCARD AFTER USE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SPILL PROC: OIL DRY OR OTHER ABSORB MATL. WASTE DISP METH: LANDFILL.
DISCHARGE TO SEWER REQS APPROVAL OF PERMITTING AUTH & MAY REQ
PRETREATMENT. VENT: GUIDELINES (USE 50% OF THE TLV).

Chemical Properties

Boiling Pt:B.P. Text:212F,100C
Spec Gravity:1.369 (H*2O=1)
pH:7.60
Solubility in Water:100% (BY WEIGHT %)
Appearance and Odor:CLEAR & COLORLESS LIQUID; SLIGHT AMMONIA ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
ALKALI, STRONG ACIDS, OXIDIZERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:OXIDES OF SULFUR, CARBON DIOXIDE,
CARBON MONOXIDE, AMMONIA.

Disposal

Waste Disposal Methods:DISP MUST BE I/A/W FED, STATE & LOCAL REGS .
RECOVER NONUSABLE FREE LIQ &/OR CONTAMD WATER & DISP IN APPRVD &
PERMITTED TREATMENT SYS; INCIN IS RECOM. REMOVE NONUSABLE SOLID
MATL &/OR CONTAMD SO IL FOR DISP IN APPRVD & PERMITTED (SUPDAT)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.